Control Unit Viofor JPS MagneticLight

Art. nr: 1038

  • for light therapy and combined therapy:
    • LED Therapy
    • Pulsed Magnetic Field LED Therapy
  • works with the all available magnetic-led applicators for contact or close to the patient’s body usage
    • small surfaces – about 20 cm2
    • medium surfaces – about 192 cm2 or about 260 cm2
    • a large area of about 560 cm2
control-unit-magneticlight

IMPLEMENTED THERAPY

Pulsed Magnetic Field LED Therapy

Combined therapy – led therapy with magneticstimulation , performed at one time from one applicator in two available modes:asynchronous

  • asynchronous
  • synchronous

Parameter settings in asynchronous mode

  • power from 10% to 100% of maximum applicator powerstep regulation of 10% with frequency filling 181,81 Hz (period 5500us)
  • step regulation of 10% with frequency filling 181,81 Hz (period 5500us)

Parameter settings in synchronous mode

  • light pulses synchronized with magnetic field pulses
  • light pulse width from 0,5 ms to 5 ms with 0,5 ms steps

Parameter settings – magnetostimulationcomplex

  • complex pemf shape signal with multi-peak structure, resulting in multiple signals across a frequency spectrum, set by a combination of three programs and three application methods
  • duration of the treatment: preset by the manufacturer: 8 min / 10 min / 12 min
  • a multiplier of the application running time
  • manual change of magnetic induction level (intensity) – levels from 0,5 to 12
  • automatic change of direction of magnetic field (polarization)

ERGONOMICS

  • intuitive interface
  • housing with carrying handle
  • volume regulation of the acoustic signal
  • recognizing connected applicators
  • stand-by mode – saving energy
  • automatic applicator diagnostics
  • suitable for continuous running

IMPLEMENTED THERAPY

LED Therapy

  • red light (R) 630 nm / 1000 mW
  • infrared (IR) 855 nm / 6800 mW
  • blue light 400 nm / 4000 mW
  • mixed light – red and infrared (RIR) – 630 nm / 500 mW and 855 nm / 3400 mW

Parameters settings

  • power from 10% to 100% of maximum applicator power
  • step regulation of 10% with frequency filling 181,81 Hz (period 5500us)
  • treatment time regulation – 1 min – 30 min with 1 min step

TECHNICAL DATA

  • type of control unit – microprocessor
  • supply voltage and frequency – 30 V/115 V ± 10 %; 50 Hz/60 Hz
  • power consumption in “stand-by” mode – <2 VA
  • maximum power consumption – <60 VA
  • max. output voltage for light impulse signal – +22 V
  • max. output voltage of magnetic field impulse signal – ± 15 V
  • frequency of the light signal in the LED Therapy mode – 181,8 Hz
  • duration of the light signal in the Led Therapy mode and asynchronous Magnetic Field LED Therapy mode – 10% – 100%
  • working mode – continuous running
  • admissible working temperature/humidity – +10 – +40°C / max 80%
  • output sockets of the control unit (for connecting applicators):
    • two round 12-pin socketsafety class – II
  • safety class – IIprotection against water – IP 40 (not waterproof)
  • protection against water – IP 40 (not waterproof)
  • maximum dimensions – 32 cm x 27 cm x 17,5 cm